E3Point


E3Point

The Honeywell E3Point is capable of detecting the widest range of toxic and combustible gases found in commercial building spaces and outbuildings, including CO, NO2, O2, H2, H2S, CH4 and C3H8. It can be used as a standalone unit with single or dual-gas detection (i.e. using a remote sensor) or deployed as a networkable device (interoperable with BACnet, Modbus or other Building Automation System); E3Point also functions with existing controller-based gas monitoring systems and wired-wireless gas monitoring system components. E3Point uses Demand Control Ventilation—through relays, Building Automation System (BAS) or controller—to increase energy savings, extend fan life and align with green building best practices. In its network configuration, E3Point also optimizes HVAC, fire/smoke, surveillance and other building systems performance. Intelligent product design reduces the unit’s cost of ownership while increasing flexibility of application. Smart sensors are pre-calibrated, auto-configure upon set-up and operate continuously on patented Reflex© technology which continuously monitors sensor cell condition and alerts user to fault status. The plug-n-play sensor cartridge, user-friendly menu and wiring options simplify installation and maintenance, and reduce the cost of gas monitoring over the life of the unit.
  • Flexible Operation
    • Comes in standalone, standalone with remote (dual gas mode) or network versions
    • Connects to analog or digital systems
    • Works with virtually any BAS including BACnet and Modbus
    • Connects to wired or wireless system (via 301CW wireless controller)
    • Wall or duct mount
    • Factory-calibrated cartridges
  • Cost Effective
    • Saves energy through Demand Control Ventilation (DCV)
    • Simplifies installation/maintenance through plug-n-play sensor
    • Remote sensor option provides dual gas monitoring (standalone version only)
    • Optimizes BAS, fire, ventilation and other security systems
  • Versatile Communications
    • Works through BAS to improve fault diagnostics and collect data on gas concentration levels, sensor condition, etc.
    • Couple with 301C to log data and daisy-chain up to 96 E3Point units
  • Advanced Sensing Technology
    • Detects CO, NO2, O2, H2, H2S, CH4, C3H8
    • Advanced electrochemical (for toxic gases)and catalytic bead (for combustible gases)  sensor performance
    • Uses patented Reflex® and smart cartridge technologies
  • Range of Accessories
    • Factory-calibrated replacement cartridges
    • Power transformer
    • Vandal-resistant steel wire detector guards
    • Tamper-proof screws
    • Horns and strobes
  • Parking Structure
  • Loading Dock Transport Terminal
  • Golf Cart Maintenance
  • Maintenance Garage
  • Hospital/Ambulance Bay
  • Fire/Police Station
  • Car Wash
  • Battery Charging Rooms
  • H2 & Hydrogen Tanks
  • Commercial Kitchen
  • Boiler Rooms
  • Uses Wall or duct-mounted gas detector for monitoring carbon monoxide (CO), nitrogen dioxide (NO2), oxygen (O2), methane (CH4), hydrogen (H2), hydrogen sulphide (H2S), and propane (C3H8), installed as a standalone device with single-gas or dual-gas monitoring.
  • Size 20.56 x 14.90 x 6.72cm (8.09 x 5.87 x 2.65”) (H x W x D); Remote Sensor: 3.5 x 4.5 x 6.5 cm (1.36 x 1.75 x 2.56”)
  • Power Requirement 24 Vac nominal (17-27Vac), 50/60 Hz, 0.35 A; 24Vdc nominal (20-38Vdc); with remote sensor: 7 W max.
  • Optional Main AC Input 120Vac nominal, ± 10% (with on-board transformer)
  • Relay Output 2 DPDT relays, 5A @ 250Vac; 5A @ 30Vdc
  • Communications 4-20mA
  • Operating Environment Commercial, Indoor, Extreme Temperature Environments
  • Operating Temperature H2S, NO2, O2, CH4, H2, C3H8: -40 to 50ºC (-40 to 122ºF) CO: -20 to 50ºC (-4 to 122ºF)
  • Sensor Type Electrochemical cell (CO, NO2, H2S, O2); catalytic (CH4, H2, C3H8,) With ECLAB T90 < 50 seconds
  • Display 8 character, 2 line backlit LCD
    • Visual Indicators Green LED: Power
    • Amber LED 1: Alarm/Fault
    • Amber LED 2: Alarm/Fault
  • Audible Alarm >85 dBA at 3 m (10 ft)
  • Accuracy ± 3% of full scale @ 25ºC
  • Electrical Certifications
    • US (ANSI/UL 61010-1)
    • Canada (CSA C22.2 No. 61010-1)