Honeywell Midas-M Silane (SiH4) Sensor, 0-20 ppm, 2 years

$326.00

Description

Honeywell Midas-M Silane (SiH4) Sensor, 0-20 ppm, 2 years

The Midas-M Sensor Cartridge enables the detection of a wide range of asphyxiant, toxic, flammable, pyrophoric, corrosive, and oxidizer gases. The plug & play Sensor Cartridge is located inside the detector’s chassis.
Gas MeasuredSilane (SiH4)
Cartridge Part NumberMMS-X2
Sensor Technology3 electrode electrochemical cell
Measuring RangeSiH40 ppm to 20 ppm
Default Alarm 12.5 ppm (rising)
Default Alarm 25 ppm (rising)
Accuracy<±5% of measured value
Exposure to SiH4 10 ppm for 5 minutes
Response Time (t62.5)Typical 5 seconds
Sensor Cartridge Life Expectancy24 months under typical application conditions
Operating Temperature0ºC to 40ºC (32ºF to 104ºF)
Effect of TemperatureZero<±0.04 ppm/ºC
Sensitivity<±0.8% of measured value/ºC
Operating Humidity (continuous)10% RH to 90% RH
Effect of HumidityZero<±0.005 ppm/% RH
Sensitivity<±2% of measured value/% RH
Operating Pressure90 kPa to 110 kPa
Effect of PositionNo effect in typical application
Long Term DriftZero<±2% ppm/year
Sensitivity<10% of measured value/year
Calibration GasSilane (2.5 ppm to 7.5 ppm, default 10 ppm)
Challenge Gas (Bump Test)Silane (10 ppm)
Warm Up Time< 20 minutes
Storage Temperature5°C to 25°C (41°F to 77°F)
Other Detectable GasesThe following additional gases can be detected with this sensor cartridge. Sensor performance and characteristics will be representative of the data as tabulated above. Consult the Technical Manual to set up the Midas®-M transmitter with the designated identification code for each of the following gas types:
Detectable GasChemical FormulaMeasuring Range
DisilaneSi2H60 ppm to 20 ppm
Cross Sensitivities

Each Midas-M sensor is potentially cross sensitive to other gases and this may cause a gas reading when exposed to other gases than those originally designated. The table below presents typical readings that will be observed when a new sensor cartridge is exposed to the cross sensitive gas (or a mixture of gases containing the cross sensitive species).
Gas / VaporChemical FormulaConcentration applied (ppm)Reading (ppm SiH4)
AmmoniaNH31000
ArsineAsH310.54
Carbon MonoxideCO20000.56
ChlorineCl25-0.86
DiboraneB2H610.75
EthanolC2H5OH5000
HydrogenH25000 0.45
Hydrogen ChlorideHCI12.52.1
Hydrogen FluorideHF100
Hydrogen SulfideH2S102.7
Iso PropanolC3H7OH20000
Nitrogen DioxideNO26-0.89
PhosphinePH311.13
Sulfur DioxideSO2503.5

Additional information

Weight 1 lbs