X-am 2500 with Cat Ex 125 PR, XXS O2, XXS CO-LC, XXS H2S-LC and Alkaline Battery Pack

$817.00

SKU: 4542262 Categories: , , Tag:

Description

Dräger X-am 2500

Dräger’s X-am® 2500 accurately detects O2, CO, NO2, SO2 and H2S and is the only 1-4 gas monitor you need in industrial and refinery applications. The X-am® 2500 combines reliable sensor technology with long battery life and intuitive operation in an instrument that defines safety.
  • Multi-gas Detector
    • 1 to 4 gas detection device
    • for personal air monitoring
    • detection of flammable gases and vapours as well as O2, CO, NO2, SO2 and H2S
  • Matrix Display-The X-am 2500 has a large, easy to read, liquid-crystal display. All gas readings are shown simultaneously and resize automatically depending on the number of sensors installed. When a gas alarm occurs, the reading for the sensor in alarm will be highlighted and will alternate with the alarm level indication of A1 or A2..
  • High Capacity Battery-The Dräger X-am 2500 can operate for more than 12 hours with either alkaline batteries or with rechargeable NiMH batteries. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle. Operating time without an Ex sensor installed is typically more than 250 hours.
  • X-Dock Compatibility-The X-am 2500 is compatible with Dräger’s X-dock testing and calibration station. X-dock is Dräger’s new solution for efficient maintenance and comprehensive equipment management. Used for functional testing and complete documentation, X-dock can complete bump tests in 8 to 15 seconds with more than 40% less gas consumption than competitive instruments1. The X-am 2500 is also compatible with the Dräger Bump Test Station.
  • Long-Lasting, Reliable Sensor Technology-The innovative, catalytic Ex sensor has a high degree of drift stability with a high resistance to silicone and hydrogen sulfide. The sensor boasts an expected service life of more than five years and is extremely sensitive to flammable gases and vapors. Further, the X-am 2500 is approved for measuring from methane to nonane, according to IEC/EN 60079-29-1.
  • Zone 0 Approved-The Dräger X-am 2500 has Ex approval for zone 0 for user safety in areas subject to explosion hazard. Additionally, it is not sensitive to electromagnetic radiation, e.g. from wireless devices and is water and dust resistant in accordance with protection class IP 67.
  • Diffusion or pump-An optional external pump with a hose up to 45 m / 147 ft long is available for use in tanks and shafts or when searching for leaks. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws.
  • Ergonomic and robust-The Dräger X-am 2500 is comfortably worn thanks to its low weight and ergonomic design and gas can enter the unit from above and from the front—even if the instrument is inside a pocket or if the front gas entry is accidentally covered.The practical two button control panel and easy menu navigation allow for intuitive operation while the integrated protective rubber coating and sensors not sensitive to shock provide additional safety in case of impacts or vibrations.
  • Peak value functionality-The X-am 2500 can store the highest gas readings for the Ex and toxic gas sensors and the lowest reading for the O2 sensor. These readings can be easily reset after a gas exposure without having to turn the monitor off and on.
    1 X-dock bump test stated times are typical results; stated gas consumption is based upon calibration gas flow of 0.3 L /minute versus 0.5 L/minute without using X-dock for bump test.
Measuring rangeCombustible gasesfrom 0 to 100% LEL in 1% increment
Oxygen (O2)from 0 to 30% vol. in 0.1% increment
Carbon monoxide (CO)from 0 to 2,000 ppm in 1 ppm increment
Hydrogen sulfide (H2S)from 0 to 500 ppm in 0.1ppm increment
Alarms360° ultra-bright indicators, 90 db sounder at 30cm, vibrating alarm
Ambient conditionsProtection ingressIP 67
Temperature-20 to +50 °C
Relative humidity10 to 95 % HR
Autonomy> 12 h to 13 h with NiMH batteries
Charging time< 4 h
Data loggerData retrievable using an infrared interface > 1000 hours for 4 gases
Recording interval1 value per minute
CertificationsATEXM1 Ex ia I Ma, II 1G Ex ia IIC T3 Ga, I M2
• Ex d ia I Mb
• II 2G Ex d ia IIC T4/T3 Gb
CSA (Canada & USA)Class I Div. 1 Group A, B, C, D T4/T3
• A/Ex ia IIC T3 /Ga
• A/Ex d ia IIC T4/ T3 /Gb
IECEx Ex ia I MaEx ia IIC T3 Ga
• Ex d ia I Mb
• Ex d ia IIC T4/ T3 Gb
Marquage CEATEX Directive 94/9/CE MED Marine Equipement Directive 96/98/CE

Additional information

Weight 1 lbs