Honeywell MIDAS Transmitter with BCl3, H2Cl2Si, HBr, HCl (all 0.72-8 ppm) Sensor Cartridge

$2,010.00

Description

Honeywell MIDAS Transmitter with Boron Trichloride (BCl3), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr), Hydrogen Chloride (HCl) (all 0.72-8 ppm) Sensor Cartridge

The Midas Gas Detector uses reliable sensor technology to detect many key toxic, ambient and flammable gases in a plant. The device monitors points up to 100 feet (30 meters) away while using patented technology to regulate flow rates and ensure error-free gas detection. Thanks to Honeywell’s use of advanced robotics, the Midas Gas Detector offers unbeatable quality and reliability:

• Improved visibility and ease of use. The Midas Gas Detector is equipped with bright LED lights and an intuitive, interactive interface that provides instant alerts to gas readings or alarm levels. The interface also includes password-protected menus for configuration, test and calibration.

• Easy installation. Compact in size with an easy-to-handle metal chassis, the Midas Gas Detector is simple to install. That’s especially important in crowded, complex process environments where space is at a premium.

• Numerous applications. With feature-rich capabilities that are easy to use, the Midas Gas Detector is suitable for many industry applications, including semiconductor processing, light industrial manufacturing, university laboratories, aerospace, wastewater and more.
  • Over 35 gases available with extended 2 year warranty*
  • Smart sensor cartridge with on board ‘e-calibration’ certificate
  • 3 built in relays (Form C) for Alarm 1, 2 and Fault
  • Power over Ethernet (PoE) communication
  • Keypad interface and remote web browser interface
  • Optional Midas Pyrolyzer module that connects to any Midas Gas Detector
  • Password protected menu levels to preserve system integrity
  • Bright LEDs and intuitive icon driven, large multicolor backlit LCD display
  • Factory-calibrated sensors to reduce need for frequent gas testing
  • Isolated 0-22 mA analog output with fault and event reporting
  • Modbus/TCP Ethernet for easy connectivity to all control and alarm systems ports for control connectivity and service interaction
  • Robust extractive pump system (2 year lifetime) sampling up to 100 feet
  • CE marked for total immunity to Radio Frequency Interference
  • Reflex® sensor health check for improved safety
  • TempraSureTM temperature compensation technology as appropriate
  • Event logging to review sensor history
  • Detects more than 35 gases error-free
  • Improved visibility and ease of use
  • Easy installation
Transmitter DimensionSize (unit with Sensor)5.91 (H) × 2.56 (W) × 6.02 (D) in (150 × 65 × 153 mm)
Weight (unit with Sensor)1.76 lb (0.8 kg)
NF3 Pyrolyzer DimensionSize (unit with Sensor)2.75 (H) × 2.48 (W) × 3.35 (D) in (70 × 63 × 85 mm)
Weight (unit with Sensor)0.9 lb (0.41 kg)
High-Temperature PFC Pyrolyzer DimensionSize (unit with Sensor)3.9 (H) × 4.0 (W) × 5.5 (D) in (100 × 101 × 140 mm)
Weight (unit with Sensor)3 lb (1.36 kg)
OP3 Pyrolyzer DimensionSize (unit with Sensor)5.2 (H) × 2.4 (W) × 3.9 (D) in (132 × 60 × 98 mm)
Weight (unit with Sensor)2.65 lb (1.20 kg)
NP1 Pyrolyzer DimensionSize (unit with Sensor)5.02 (H) × 2.56 (W) × 5.29 (D) in (128 × 65 × 134 mm)
Weight (unit with Sensor)1.8 lb (0.81 kg)
Power RequirementsOperating Voltage24VDC, -15 to +10%
Operating Voltage with Power over Ethernet (PoE)48 VDC via PoE
Power ConsumptionTransmitter Unit<5 W
With Pyrolyzer (Option)<12.95 W
With Lonworks<8 W
With Lonworks and Pyrolyzer<15.95 W
OutputsVisualAlarm, Power and Fault LEDs, LCD display with all gas readings and events
Relays3 relays for Alarm1, Alarm 2 and Fault rated 30VDC, 1 A or 125VAC, 0.5 A; configurable NO or NC, latched or unlatched
Analog3 wire sink, 3 wire source or 4 wire fully isolated, 0 to 21mA
Digital CommunicationsModbus, TCP Ethernet, Power over Ethernet (PoE), Lonworks
Service PortRS232C, PPP protocol
Certification and SpecificationCE marked Meets EN 50270:2006 (Type2) and EN 61000-6-4:2007 ETL approved UL 61010-1 Ed:3 IEEE 802.3af-2003
PerformanceRefer to Individual Cartridge Datasheets
Transport SystemFlow Rate500 mL/min
Transport Time2 to 30 seconds maximum
Sample Line Tubing0.125 in ID × 0.25 in OD
Tubing LengthUp to 100 ft (30 m) with FEP tubing
Exhaust Line Tubing0.25 in ID × 0.375 in OD
Exhaust LengthUp to 100 ft (30m)
Ambient PointIn line air filter required
Operating TemperatureUnit with Sensor32° to 104°F (0° to 40°C)
Unit with Sensor and Pyrolyzer32° to 86°F (0° to 30°C)
Wiring Requirement4-20mA2 wire, 14 AWG maximum
DigitalCAT5 Cable or equivalent; RJ45 connector
Gas Concentration Display and InterfaceInstrument4-digit alphanumeric display with separate units, flow rate bar graph and other icon driven indicators
4 button interface keypad
RemoteOption for PC / PDA Internet browser access via Ethernet
WarrantyTransmitter Unit1 year
Sensor cartridge1 year standard, 2 years extended warranty
Expected Pyrolyzer LifeMIDAS-T-00P: 1 year
MIDAS-T-NP1: 2 years
Installation DetailsMountingWall mounted using pre-drilled holes on chassis. Options for DIN rail or vertical bracket mounting.
RemoteCover: Painted steel
Chassis/Mounting Bracket: Zinc plated steel

Additional information

Weight 1.76 lbs
Dimensions 1.38 × 3.93 × 5.91 in