EVM
EVM
The EVM Series Particulate Mass Concentration and Air Quality Monitors simultaneously measure particulates and gas concentration in real-time.
- Particulate, gas and photoionization detector (PID) measurement from a single device
 - Less equipment to carry to job site; compact, user-friendly design
 - 90-degree light scattering laser photometer measures particulates in real-time
 - Proprietary technology for selecting particulate settings; no need for external cyclones
 - Built in sampling pump allows for gravimetric analysis
 - Large, easy-to-read display with trend graphing for measurements
 - Time history data logging and compatibility with Detection Management Software makes analysis efficient
 
								EVM Monitor Specifications
EVM Sensor Specifications
						 
												 
												 | General | |
| Display Languages | English, French, German, Italian, Portuguese, and Spanish | 
| User Interface | 10 pushbuttons and 4 softkeys, menu driven | 
| Display Type | Transreflective 128 x 64 LCD with backlighting | 
| Software Compatibility | TSI Quest Detection Management Software DMS | 
| Standards | CE Mark and RoHS compliant | 
| Particulate Impactors Size Fractions | PM2.5, PM4, PM10 or TSP (within the instrument’s measurement range)  | 
| Flow Rate | 1.67 L/min | 
| Displayed Data | |
| Measurements | Level, Minimum, Maximum, Average, Short-Term Exposure Level (STEL), Time Weighted Average (TWA) | 
| Real-Time Measurement | Once per second display update rate | 
| Time History Data Logging Intervals | Seconds: 1, 5, 15, 30 | 
| Minutes: 1, 5, 10, 15, 30, 60 | |
| Trend Graphing Intervals for All Parameters | Minutes: 1.5, 3, 15 | 
| Hours: 1.5, 3, 8, 12, 24 | |
| Status Indicators | Battery, Run, Stop, Overload and UnderRange | 
| Averaging Time | 1 to 30 seconds | 
| Physical Characteristics | |
| Size | 7.5” x 7.5” x 2.75” (19 cm x 19 cm x 7 cm) | 
| Weight | 2.9 lb (1.3 kg) | 
| Housing | Static dissipative ABS Polycarbonate housing | 
| Tripod Mount | Standard photographic mount on bottom, 1/4” - 20 screw heads | 
| Operating Conditions | |
| Temperature Range | 32 °F - 122 °F (0 °C to 50 °C) | 
| Pressure Range | 65 kPa to 108 kPa | 
| Relative Humidity Range | 10% to 90% non-condensing | 
| Storage Conditions | |
| Temperature | -4 °F to 140 °F (-20 °C to 60 °C) | 
| Humidity | 0% to 95% RH, non-condensing | 
| Electrical Characteristics | |
| Intelligent Sensors | Auto-detectable when inserted at power-off mode | 
| Battery Pack | Rechargeable lithium-ion | 
| Battery Life | Minimum of 8 hours under continuous operation | 
| External DC Power Input | 10 to 16 Volt power inlet (nominal 12V DC) 1.5A | 
| Power Adapter | Universal AC adapter 100 to 240 Volt AC, 50-60 Hz | 
| Method | Base Units | Display Resolution | Display Range | Accuracy Repeatability | 
|---|---|---|---|---|
| VOC: 10.6eV Photoionization Detector | ||||
| Low Sensitivity PID | select ppb or mg /m3 | 0.01 | 0.00 - 2,000 | +/-5% / 2%*** at calibration level | 
| High Sensitivity PID | select ppb or μg /m3 | 1 | 0 - 50,000 | +/-5% / 2%*** at calibration level | 
| CO2 | ||||
| NDIR (Non-Dispersive Infrared)  | ppm | 1 | 0 - 5,000 ppm; autoranging (Noncondensing) | +/-100 ppm @ 20 deg C, 1 bar pressure at 2,000 ppm applied gas | 
| Temperature | ||||
| Junction Diode | deg C | 0.1 | 0.0 - 60.0 | +/- 1.1 deg C | 
| deg F | 0.1 | 32.0 - 140 | +/- 2 deg F | |
| Relative Humidity | ||||
| Capacitive | % humidity | 0.1 | 0.0 - 100 | +/-5% RH* of signal between 10%-90% | 
| Air Velocity | ||||
| Omni-directional Heated Thermistor Windprobe | meter/sec | 0.1 | 0.0 - 20 | +/-0.12 m/s + 4.5% of signal | 
| feet/min | 1 | 0 - 3940 | +/-23.6 ft/min + 4.5% of signal | |
| Particulates | ||||
| 90° Light Scattering / Integrating Photometer | mg / m3 | 0.001 | 0.000 - 200.0 | +/-15% (rel ARD*) | 
| μg / m3 | 1 | 0 - 20,000 | +/-15% (rel ARD*) | |
| Particulates Size Range | μm | N/A | 0.1 - 10 | ** | 
| Electrochemical Sensor | ||||
| CO - Carbon Monoxide Sensor | ppm | 1 | 0 - 1,000 | +/-5% / 2% of signal | 
| Cl2 - Chlorine Sensor | ppm | 0.1 | 0.0 - 20 | +/-5% / 2% of signal | 
| EtO - Ethylene Oxide Sensor | ppm | 0.1 | 0.0 - 20 | +/-5% / 2% of signal | 
| HCN - Hydrogen Cyanide Sensor | ppm | 0.1 | 0.0 - 50 | +/-5% / 2% of signal | 
| H2S - Hydrogen Sulfide Sensor | ppm | 1 | 0.0 - 500 | +/-5% / 2% of signal | 
| NO - Nitric Oxide Sensor | ppm | 0.1 | 0.0 - 100 | +/-5% / 2% of signal | 
| NO2 - Nitrogen Dioxide Sensor | ppm | 0.1 | 0.0 - 50 | +/-5% / 2% of signal | 
| O2 - Oxygen Sensor | % | 0.1 | 0.0 - 30 | +/-5% / 2% of signal | 
| SO2 - Sulfur Dioxide Sensor | ppm | 0.1 | 0.0 - 50 | +/-5% / 2% of signal | 
EVM Model Comparison
| EVM-3 | EVM-4 | EVM-7 | |
|---|---|---|---|
| EVM Monitor Types | Particulate Monitor (no indoor air quality monitor) | Indoor Air Quality Monitor (no particulates) | Indoor Air Quality/Particulate Monitor (eliminates the need for separate meters) | 
| Temperature | + | + | + | 
| Relative Humidity | + | + | + | 
| Air Velocity (With Purchase of Optional Accessory) | + | + | + | 
| Particulates (Mass Concentration) | + | + | |
| Toxic Gas (Choose from 9 Sensors) | + | + | |
| Carbon Dioxide | + | + | |
| Select Volatile Organic Compounds | + | 
	