Description
Also includes flash drive, USB cable, tubing, and demand flow regulator.
SDM-03 without AC Adaptor
(Requires AC adaptor, Part # 49-2058RK-04)
The SDM-03 is a versatile maintenance tool that automates the testing service of a 03 Series portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).
Multi Module System
Automate how you manage and service 03 Series instruments by connecting the SDM-03 to a computer with a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, or archive data for up to ten instruments. Also, download the data logging history from each instrument into one easy to manage locator. SDM-03 stations can be manifolded together to reduce the number of demand flow regulator gas cylinders required.
User Guide Poster Each SDM-03 ships with a pictorial wall chart user guide. This guide gives the already easy to use cal station a simple pictorial easy step by step guide to calibrating or bump testing a 03 Series. It’s ideal to hang in an instrument shop or wherever the SDM-03 is located.
Multi Module System
Automate how you manage and service 03 Series instruments by connecting the SDM-03 to a computer with a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, or archive data for up to ten instruments. Also, download the data logging history from each instrument into one easy to manage locator. SDM-03 stations can be manifolded together to reduce the number of demand flow regulator gas cylinders required.
User Guide Poster Each SDM-03 ships with a pictorial wall chart user guide. This guide gives the already easy to use cal station a simple pictorial easy step by step guide to calibrating or bump testing a 03 Series. It’s ideal to hang in an instrument shop or wherever the SDM-03 is located.
Stand Alone Station
- Stand-alone station (no PC Required)
- Calibration
- Bump Test
- Save Bump Test and Calibration records
- Bump test and calibration records copy to USB jump drive
- Includes PC software for viewing/ archiving bump test and calibration records
Multi Module System
- Multiple modules connected to a PC (10 max)
- Calibration
- Bump Test
- Automatic calibration/bump test option
- Configure 03 Series parameters
- Archive Bump Test and Calibration records
- Archive data to network location
- Software controlled data retrieval
- Windows 7 compatible
Multi Module System
-
- Multiple modules connected to a PC (10 max)
- Calibration
- Bump Test
- Automatic calibration/bump test option
- Configure 03 Series parameters
- Archive Bump Test and Calibration records
- Archive data to network location
- Software controlled data retrieval
- Windows 7 compatible
Input Power | 12 VDC NOTE: AC Adapter with 100 – 240 VAC, 50/60 Hz,0.6A input and 12 VDC, 1.2A output provided as standard. |
Environmental Conditions | For Indoor Use Only -10° C to 40° C, below 80% Relative Humidity, Non-Condensing |
Applicable Instruments | 03 Series |
Maximum Number of Records Saved | 200 (stand-alone). Unlimited with software |
3 Ports | 1 Calibration gas 1 fresh air 1 exhaust |
Standard Accessories | AC Adapter USB Flash Drive Single Module Data Viewer Software SDM-03 Docking Station PC Controller Program Inlet Air Filter Instruction Manual 10 Foot Long Exhaust Tube One 3 Foot Long Tube for GAS Fitting 2 T-Fittings (for PC Controlled Configuration only) 10 Foot Long 3/16 Inch Tube for GAS manifold- ing (used for PC Controlled Configuration only) Check Valve (used for PC Controlled Configuration only) USB Cable, Type A to Type B |
SDM-03 Datasheet
SDM-03 User Manual
SDM-03 Standalone Configuration Operator's Manual
SDM-03 PC Controlled Configuration Operator's Manual
SDM-03 User Manual
SDM-03 Standalone Configuration Operator's Manual
SDM-03 PC Controlled Configuration Operator's Manual